<rss version="2.0">
    <link rel="self" type="application/atom+xml" href="/rss/1/productlistings/data-loggers/cat13"/>
      <link rel="first" href="/rss/1/productlistings/data-loggers/cat13"/>
          <link rel="last" href="/rss/1/productlistings/data-loggers/cat13?page=1"/>
    <channel>
    <title>Data Loggers from Complete Safety Supplies</title>
    <link>http://www.completesafetysupplies.co.uk/rss/1/productlistings/data-loggers/cat13</link>
    <description>&lt;p&gt; &lt;/p&gt;
&lt;h1&gt;&lt;span style=&quot;font-size: 11.0pt; line-height: 115%;&quot;&gt;Data Loggers&lt;/span&gt;&lt;/h1&gt;
&lt;p class=&quot;MsoNormal&quot;&gt; &lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;ETI has used its vast experience in temperature measurement, together with the latest technology, to create the ThermaData range of small, cost-effective, data-loggers.&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;Unlike many loggers on the market today, they have been designed for ease of use and with reliability very much in mind.&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;What are data-loggers?&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;Data-loggers are electronic devices that record temperature over a period of time for analysis at a later date. The user chooses what information is required and the data-logger records it.&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;The data-loggers incorporate a thermistor sensor that measures the temperature, and the data-loggers internal microprocessor chip then stores the data.&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;The stored data can then be transferred to a computer, via a USB cradle, for further analysis at a time convenient to the user.&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt; &lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;Applications for data-loggers&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;There are many uses for data-loggers, for example, to ensure compliance with legislation, to help save costs, to ensure the quality of a product, process, or for research purposes in the following industries&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;food processing&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;environment&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;agriculture&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;logistics&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;laboratories&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;museums &amp;amp; archives&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;refrigeration&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;medical&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;The EC food industry directive suggests that organisations involved in food preparation, storage or transportation should have the ability to verify that the temperature of food has been kept at the correct levels.&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;This is often referred to as due diligence.&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;Data-loggers offer organisations a method of complying with food industry legislation by offering traceability from the moment the food is received to the time it is delivered to the customer.&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;For shippers, data-loggers can verify that conditions within the transportation vehicles have been maintained within the specified levels.&lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;For growers of fresh produce, data-loggers provide an accurate record of temperatures during the life cycle of a product, from farm to plate, i.e. during growth, preparation and transportation of produce, thus ensuring best quality. &lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;Monitoring the environment can help organisations ensure that HVAC systems are used to the optimum, keeping energy use to a minimum and saving money. &lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;strong style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;UKAS Certificates of Calibration&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;Traceable certificates of calibration are available for most of the Data Loggers available on our site (BRC standards require calibration of all measuring and monitoring devices to be traceable back to a nationally recognised standard).&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;  &lt;/span&gt;. &lt;/span&gt;&lt;/p&gt;
&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 8.5pt; line-height: 115%;&quot;&gt;Each certificate indicates deviations from standards at three temperature or humidity check points.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt; &lt;/p&gt;</description>
    <copyright>Copyright 2026 Complete Safety Supplies</copyright>
    <language>en</language>
    <lastBuildDate>Fri, 29 Nov 2024 23:45:08 +0000</lastBuildDate>
    <pubDate>Fri, 29 Nov 2024 23:45:08 +0000</pubDate>
              <item>
              <pubDate>Tue, 04 Jul 2023 13:05:05 +0100</pubDate>
              <title>Cold Chain Data Logger (Pack Of 10)</title>
              <description><a href="/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/cold-chain-data-logger-pack-of-10-p1249"><img src="data:image/gif;base64,R0lGODlhAQABAIAAAAAAAP///yH5BAEAAAAALAAAAAABAAEAAAIBRAA7" data-src="https://www.completesafetysupplies.co.uk/images/products/thumbnails/1504882477-63568200.jpg" alt="Cold Chain Data Logger (Pack Of 10)"  class="lazyload" /></a>
<p><a href="/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/cold-chain-data-logger-pack-of-10-p1249">Cold Chain Data Logger (Pack Of 10)</a></p>
<p>Cold Chain Data Logger (Pack Of 10)

Battery lasts for 12 months
Data downloadable in PDF, Microsoft Excel and JPEG formats
One button start with easy to use free software
Pre-programed temperature alarm limits and sample rates

Spec

Chilled Goods - Pre-set alarms Low 2°C &amp;amp; High 8°C
Frozen Goods - Pre-set alarms Low -20°C - High -16°C
Ripening Goods - Pre-set alarms Low 12°C - High 14°C
Sample Rates: Every 10 minutes – all versions&amp;nbsp;
Battery Life: 12 months (minimum)
Accuracy:&amp;nbsp; ±0.5°C
Resolution 0.1°C
Status notification: Red &amp;amp; Green LEDs
Size: 67mm x 48mm
</p></description>
              <guid>/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/cold-chain-data-logger-pack-of-10-p1249</guid>
              <link>/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/cold-chain-data-logger-pack-of-10-p1249</link>
            </item>
          <item>
              <pubDate>Fri, 29 Nov 2024 23:45:08 +0000</pubDate>
              <title>Data Logger Colour Seals</title>
              <description><a href="/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-colour-seals-p52"><img src="data:image/gif;base64,R0lGODlhAQABAIAAAAAAAP///yH5BAEAAAAALAAAAAABAAEAAAIBRAA7" data-src="https://www.completesafetysupplies.co.uk/images/products/thumbnails/1295437961-19084800.jpg" alt="Data Logger Colour Seals"  class="lazyload" /></a>
<p><a href="/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-colour-seals-p52">Data Logger Colour Seals</a></p>
<p>Data Logger Colour Coded Seals

Coloured seals for colour-coding data loggers.&amp;nbsp;

supplied in pack of 7 different colours
can be used for easy identification
</p></description>
              <guid>/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-colour-seals-p52</guid>
              <link>/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-colour-seals-p52</link>
            </item>
          <item>
              <pubDate>Fri, 29 Nov 2024 23:45:08 +0000</pubDate>
              <title>Data Logger Protective Boot</title>
              <description><a href="/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-protective-boot-p53"><img src="data:image/gif;base64,R0lGODlhAQABAIAAAAAAAP///yH5BAEAAAAALAAAAAABAAEAAAIBRAA7" data-src="https://www.completesafetysupplies.co.uk/images/products/thumbnails/1295440343-97010100.jpg" alt="Data Logger Protective Boot"  class="lazyload" /></a>
<p><a href="/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-protective-boot-p53">Data Logger Protective Boot</a></p>
<p>Data Logger Protective Boot

Data logger protective rubber boot for ThermaData loggers.

protects against accidental damage
made from durable silicone rubber
</p></description>
              <guid>/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-protective-boot-p53</guid>
              <link>/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/eti-data-logger-protective-boot-p53</link>
            </item>
          <item>
              <pubDate>Tue, 04 Jul 2023 13:05:05 +0100</pubDate>
              <title>EL-USB-1 Temperature Data Logger with USB interface</title>
              <description><a href="/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/corintech-el-usb-1-temperature-data-logger-with-usb-interface-p786"><img src="data:image/gif;base64,R0lGODlhAQABAIAAAAAAAP///yH5BAEAAAAALAAAAAABAAEAAAIBRAA7" data-src="https://www.completesafetysupplies.co.uk/images/products/thumbnails/1627375364-91530300.jpg" alt="EL-USB-1 Temperature Data Logger with USB interface"  class="lazyload" /></a>
<p><a href="/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/corintech-el-usb-1-temperature-data-logger-with-usb-interface-p786">EL-USB-1 Temperature Data Logger with USB interface</a></p>
<p>Temperature Data Logger with USB interface


-35 to +80°C (-31 to +176°F) measurement range
USB interface for set-up and data download
User-programmable alarm thresholds
Status indication via red, green and orange LEDs
Supplied with replaceable internal lithium battery and Windows control software
Environmental protection to IP67
UKAS 4 point calibration service available for this product, please enquire.

This standalone USB-T Temperature&amp;nbsp;data logger measures and stores up to 16,382 temperature readings over a -35 to +80°C (-31 to +176°F) range.
Its intuitive design makes it easy to set up the logging rate and start-time. As well as download the stored data by plugging the data logger into a PC&amp;rsquo;s USB port and running the purpose designed software under Windows 2000, XP and Vista (32-bit). Data can then be graphed, printed and exported to other applications. The temperature data logger is supplied complete with a long-life lithium battery which can typically allow logging for 1 year. Correct functioning of the unit is indicated by flashing red, green and orange LEDs.</p></description>
              <guid>/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/corintech-el-usb-1-temperature-data-logger-with-usb-interface-p786</guid>
              <link>/measuring-devices-c156/temperature-monitoring-c18/data-loggers-c13/corintech-el-usb-1-temperature-data-logger-with-usb-interface-p786</link>
            </item>
          </channel>
</rss>